SolepowerGet a quote
All packages

Enterprise · Solepower Business 72

Our Largest Standard System, for Sites That Run All Day

73.2 kWp solar · 72 kVA inverter · 180 kWh lithium battery

From ₦57,830,000.00

Choose your configuration below. Confirm current pricing and installation scope in a written quotation.

Jinko solar panel
118 panels
Hybrid inverter, illustrative model
6 inverters
Lithium battery, illustrative model
180 kWh battery

Equipment overview · exact models confirmed in your quote

73.2 kWpSolar array
72 kVAInverter capacity
180 kWhBattery storage
280.2 kWhModelled daily generation

Choose your configuration.

Compare equipment and battery capacity. Start with your actual loads and preferred backup hours.

Starter
Jinko solar panel
96 panels
Hybrid inverter, illustrative model
6 inverters
Lithium battery, illustrative model
150 kWh battery

Solepower Business 72 Starter

₦57,830,000.00

  • 59.5 kWp solar · 96 panels
  • 6 × SRNE 12kW hybrid
  • 150 kWh lithium battery
Request starter quote

Add 22 panels and a sixth 30kWh pack later.

Published package figures are planning references. Confirm current equipment, availability and installation scope. Discuss payment options.

Is this the right fit?

Large hotel, light manufacturing or estate common services on a three-phase supply

Hotel with 40 or more rooms, a pool, kitchen and laundry

Light manufacturing or packaging with daytime production

Residential estate powering pumps, gatehouses and street lighting

Institutional client looking at Energy as a Service: no upfront capital, a fixed monthly tariff

What this system can power.

Air conditioning

20 or more units, or 6–8 commercial units

Six inverters, two per phase, keep a three-phase site balanced.

refrigeration

Large-scale cold storage around the clock

lighting

Full site lighting including perimeter and street lighting

fans

All

entertainment devices

100 or more devices, workstations and servers

water pump

Multiple pumps up to 5HP

washing machine

Industrial laundry: yes, within the inverter rating

microwave

Full commercial kitchen: yes

Loads to discuss before ordering

Large motor and harmonic-heavy loads must be reviewed by an Solepower engineer. Site survey and load audit required. Above 72kVA we design high-voltage systems individually.

Understand your battery runtime.

162 kWhUsable battery capacity
4.5 hoursAt 36 kW — the working day's cooling and equipment
3 hoursAt 54 kW — the full site load

Overnight scenario

At a typical night-time load of 18kW (security, cold storage, pumps and occupied areas), the 180kWh battery runs for about 9 hours. The cheaper version's 150kWh runs for about 7.5 hours.

Estimates vary with actual load, battery reserve, temperature and conversion losses.

SEE THE ENERGY MOVE

Watch a day on this system.

Follow solar, battery and generator power through 24 hours. Change the building, weather or configuration to explore how the system responds with the grid off.

Building

00:00Night · grid off

Drag to rotate · arrow keys to turn

Solar available0 kW
Building demand0 kW
Usable battery charge0%
Generator output0 kW
Solar availableBuilding demandGeneratorBattery charge

Solar captured
Building energy
Lowest usable charge
Generator energy
View hourly energy data
Instantaneous power and battery charge, hourly samples
HourSolar kWLoad kWGenerator kWBattery %

The same day on diesel.

Compare generator fuel for the entire load with the generator backup required in this simulation.

Generator only
Solar + generator backup
Illustrative daily fuel saving
Simulation assumptions and limits

Illustrative model, not live monitoring or a measured weather forecast. The package’s modelled daily solar energy is distributed from 6am to 6pm. Weather multipliers are 125%, 100%, 55% and 25%; they are scenarios, not annual frequency claims. Home demand is weighted towards evenings; business demand towards 8am–6pm, with 35% more daily energy. Adjust daily load from 50% to 200%.

Battery usable capacity is 90% of nominal, starting at 75% of usable capacity at midnight. Charge and discharge efficiency are each 96%. Solar and battery delivery are limited to 90% of inverter kVA in kW. Generator power fills remaining demand, without charging the battery. This is a single illustrative day; its opening and closing battery charge may differ.

Fuel use per hour = 0.25 × supplied kW + 0.037 × generator kVA while running; generator rating is assumed equal to package inverter kVA. Fuel only; servicing, replacement, financing and grid costs are excluded.

Every detail, clearly listed.

Complete configuration specifications
Solar array73.2 kWp
Panels118 × Jinko Tiger Neo 620W N-type TOPCon (Tier-1)
Inverter6 × SRNE 12kW hybrid
PhaseThree-phase (two inverters per phase), or single-phase
Battery storage180 kWh
Battery chemistryLiFePO₄
Battery rating7-year warranty, over 6,000 cycles at 90% depth of discharge
Usable battery capacity162 kWh
Modelled daily generation280.2 kWh
Modelled monthly generation8406 kWh

Explore the savings estimates.

Illustrative scenarios from this package’s existing planning model. Savings and payback are estimates, not guaranteed returns.

conservative

₦2,772,000.00modelled monthly savings

2 years estimated payback

base case

₦4,018,000.00modelled monthly savings

1.4 years estimated payback

optimistic

₦4,730,000.00modelled monthly savings

1.2 years estimated payback

FOLLOW THE RETURN OVER TIME

Your payback, made visible.

Adjust the assumptions to see cumulative savings cross the package investment.

Estimated simple payback—

Configuration investment: · follows the simulation configuration above.

Cumulative savings after maintenanceInitial investment
Year 10
Cumulative savings
Net after investment
Investment recovered

Simple, undiscounted estimate from the selected package’s savings assumptions. Defaults exclude maintenance until you enter a value. Financing, tariff changes, tax, inflation, replacement batteries and residual value are excluded. The day simulation and this long-term estimate are separate models; one day’s result is not multiplied into an annual guarantee.

Assumptions behind these estimates

Savings are the solar energy a system produces and the customer uses, valued at what that energy costs them today. Output is 1,397kWh per kWp a year, the Lagos figure for a well-oriented, unshaded array after system losses; we count 75% of it as used in homes and 90% in businesses, and give the battery no credit for charging from the grid, so the payback is conservative. Generator fuel is derived rather than assumed: litres/hour ≈ 0.25 × kW drawn + 0.037 × rated kVA, at ₦1,920/litre. The second term is fixed burn proportional to the set's size whether or not anything is plugged in, which is why an oversized generator costs more per kWh than one that is worked hard. Most Lagos generators run at 40–70% of rating; across that band fuel alone costs ₦607–₦702/kWh on a well-maintained engine, about ₦640/kWh at a typical 55% load, and around ₦800/kWh on a worn, lightly loaded one. Servicing, overhaul, managed-power premiums and diesel theft add another ₦60–₦120/kWh, which is what takes generator power past ₦700/kWh all-in. Band A grid is taken at ₦210/kWh. Conservative (₦366/kWh blended avoided cost): Band A home, 14–18 hours of mains, load weighted to the evening. Base case (₦531/kWh): Band B/C small business, roughly 10 hours of mains, mid-life generator. Optimistic (₦625/kWh): Band C/D commercial site with minimal grid and heavy daytime load. The more of your consumption falls in daylight hours, the faster the payback.

Pricing and sizing methodology

A clearer view of generator costs.

A 80kVA generator running 16 hours a day burns roughly 4,490–6,800 litres of diesel a month, depending on how hard it is worked. At ₦1,920 a litre that is ₦8.6M–₦13.1M a month in fuel alone, before servicing, oil changes and the diesel that goes missing. Ask about Energy as a Service for a zero-capex supply.

Fuel prices are model assumptions. Check the diesel price guide and request a site-specific comparison.

YOUR SPACE. YOUR POWER NEEDS.

Let’s build your power plan.

Tell us your location, appliances and backup needs. We’ll help confirm the right configuration and an itemised quotation.

Explore compatible system monitoring