Solepower Business 36 Starter
₦26,915,000.00
- 29.8 kWp solar · 48 panels
- 3 × SRNE 12kW hybrid
- 60 kWh lithium battery
Add 12 panels and a third 30kWh pack later.
Commercial · Solepower Business 36
37.2 kWp solar · 36 kVA inverter · 90 kWh lithium battery
From ₦26,915,000.00
Choose your configuration below. Confirm current pricing and installation scope in a written quotation.



Equipment overview · exact models confirmed in your quote
Compare equipment and battery capacity. Start with your actual loads and preferred backup hours.
Published package figures are planning references. Confirm current equipment, availability and installation scope. Discuss payment options.
Office floor, school or larger restaurant on a three-phase supply, running a 30kVA generator
Office floor with 30–50 staff and 8–10 AC units
Private school running classrooms, labs and an admin block
Restaurant or event space with cold rooms and heavy lunchtime load
Small hotel running rooms and a kitchen
8–10 units (1.5HP) in the day
One inverter per phase keeps the three phases balanced.Cold rooms, chillers and freezers around the clock
Full premises lighting inside and out
All
40–60 workstations, servers and network equipment
Up to 2HP pumps: yes
Yes, including small commercial machines
Commercial kitchen equipment: yes, within the inverter rating
Large motor loads and lifts. These need a load audit first.
At a typical night-time load of 9kW (cold rooms, CCTV, security lights and a few ACs), the 90kWh battery runs for about 9 hours. The cheaper version's 60kWh runs for about 6 hours.
Estimates vary with actual load, battery reserve, temperature and conversion losses.SEE THE ENERGY MOVE
Follow solar, battery and generator power through 24 hours. Change the building, weather or configuration to explore how the system responds with the grid off.
Drag to rotate · arrow keys to turn
| Hour | Solar kW | Load kW | Generator kW | Battery % |
|---|
Compare generator fuel for the entire load with the generator backup required in this simulation.
Illustrative model, not live monitoring or a measured weather forecast. The package’s modelled daily solar energy is distributed from 6am to 6pm. Weather multipliers are 125%, 100%, 55% and 25%; they are scenarios, not annual frequency claims. Home demand is weighted towards evenings; business demand towards 8am–6pm, with 35% more daily energy. Adjust daily load from 50% to 200%.
Battery usable capacity is 90% of nominal, starting at 75% of usable capacity at midnight. Charge and discharge efficiency are each 96%. Solar and battery delivery are limited to 90% of inverter kVA in kW. Generator power fills remaining demand, without charging the battery. This is a single illustrative day; its opening and closing battery charge may differ.
Fuel use per hour = 0.25 × supplied kW + 0.037 × generator kVA while running; generator rating is assumed equal to package inverter kVA. Fuel only; servicing, replacement, financing and grid costs are excluded.
| Solar array | 37.2 kWp |
|---|---|
| Panels | 60 × Jinko Tiger Neo 620W N-type TOPCon (Tier-1) |
| Inverter | 3 × SRNE 12kW hybrid |
| Phase | Three-phase (one inverter per phase), or single-phase |
| Battery storage | 90 kWh |
| Battery chemistry | LiFePO₄ |
| Battery rating | 7-year warranty, over 6,000 cycles at 90% depth of discharge |
| Usable battery capacity | 81 kWh |
| Modelled daily generation | 142.4 kWh |
| Modelled monthly generation | 4272 kWh |
Illustrative scenarios from this package’s existing planning model. Savings and payback are estimates, not guaranteed returns.
conservative
₦1,409,000.00modelled monthly savings2 years estimated payback
base case
₦2,042,000.00modelled monthly savings1.4 years estimated payback
optimistic
₦2,404,000.00modelled monthly savings1.2 years estimated payback
FOLLOW THE RETURN OVER TIME
Adjust the assumptions to see cumulative savings cross the package investment.
Configuration investment: · follows the simulation configuration above.
Simple, undiscounted estimate from the selected package’s savings assumptions. Defaults exclude maintenance until you enter a value. Financing, tariff changes, tax, inflation, replacement batteries and residual value are excluded. The day simulation and this long-term estimate are separate models; one day’s result is not multiplied into an annual guarantee.
Savings are the solar energy a system produces and the customer uses, valued at what that energy costs them today. Output is 1,397kWh per kWp a year, the Lagos figure for a well-oriented, unshaded array after system losses; we count 75% of it as used in homes and 90% in businesses, and give the battery no credit for charging from the grid, so the payback is conservative. Generator fuel is derived rather than assumed: litres/hour ≈ 0.25 × kW drawn + 0.037 × rated kVA, at ₦1,920/litre. The second term is fixed burn proportional to the set's size whether or not anything is plugged in, which is why an oversized generator costs more per kWh than one that is worked hard. Most Lagos generators run at 40–70% of rating; across that band fuel alone costs ₦607–₦702/kWh on a well-maintained engine, about ₦640/kWh at a typical 55% load, and around ₦800/kWh on a worn, lightly loaded one. Servicing, overhaul, managed-power premiums and diesel theft add another ₦60–₦120/kWh, which is what takes generator power past ₦700/kWh all-in. Band A grid is taken at ₦210/kWh. Conservative (₦366/kWh blended avoided cost): Band A home, 14–18 hours of mains, load weighted to the evening. Base case (₦531/kWh): Band B/C small business, roughly 10 hours of mains, mid-life generator. Optimistic (₦625/kWh): Band C/D commercial site with minimal grid and heavy daytime load. The more of your consumption falls in daylight hours, the faster the payback.
Pricing and sizing methodologyA 30kVA generator running 12 hours a day burns roughly 1,260–1,910 litres of diesel a month, depending on how hard it is worked. At ₦1,920 a litre that is ₦2.4M–₦3.7M a month in fuel alone, before servicing, oil changes and the diesel that goes missing. This system moves the working day onto solar and covers outages from the battery.
Fuel prices are model assumptions. Check the diesel price guide and request a site-specific comparison.
YOUR SPACE. YOUR POWER NEEDS.
Tell us your location, appliances and backup needs. We’ll help confirm the right configuration and an itemised quotation.
Explore compatible system monitoring