SolepowerGet a quote
All packages

SME/Residential · Solepower Home 11

10 to 12kVA of Power, at the Lowest Price on Our List

8.7 kWp solar · 11 kVA inverter · 30 kWh lithium battery

From ₦6,930,000.00

Choose your configuration below. Confirm current pricing and installation scope in a written quotation.

Jinko solar panel
14 panels
Hybrid inverter, illustrative model
1 inverter
Lithium battery, illustrative model
30 kWh battery

Equipment overview · exact models confirmed in your quote

8.7 kWpSolar array
11 kVAInverter capacity
30 kWhBattery storage
33.3 kWhModelled daily generation

Choose your configuration.

Compare equipment and battery capacity. Start with your actual loads and preferred backup hours.

Starter
Jinko solar panel
12 panels
Hybrid inverter, illustrative model
1 inverter
Lithium battery, illustrative model
15 kWh battery

Solepower Home 11 Starter

₦6,930,000.00

  • 7.4 kWp solar · 12 panels
  • Aurora 11kW hybrid
  • 15 kWh lithium battery
Request starter quote

Add 2 panels and a second 15kWh pack later to reach 8.7kWp and 30kWh.

Published package figures are planning references. Confirm current equipment, availability and installation scope. Discuss payment options.

Is this the right fit?

3–4 bedroom home or small office shopping for a 10 or 12kVA system on a budget

3–4 bedroom flat or duplex running 2 ACs in the evening

Small office or shop with 2–3 AC units and computers

Household replacing a 10–12kVA generator

Buyer who wants a 30kWh battery without paying for a premium inverter

What this system can power.

Air conditioning

2 units (1.5HP) together, a third in sunshine hours

11kW carries 2 split units plus the base load, with room for a third while the panels are producing.

refrigeration

1 fridge and 1 freezer around the clock

lighting

Full property LED lighting inside and out

fans

4–5 ceiling fans

entertainment devices

3 TVs and 5 laptops or workstations

water pump

0.75–1HP borehole pump: yes

washing machine

Yes, 1–2 loads a day

microwave

Yes, moderate daily use

Loads to discuss before ordering

Sites that expect to grow beyond 11kVA. The Aurora 11kW runs on its own and cannot be paired with a second inverter, so choose Home 12 if you may add capacity later.

Understand your battery runtime.

27 kWhUsable battery capacity
4.9 hoursAt 5.5 kW — 2 ACs, fridge and lights
3.4 hoursAt 8 kW — 2 ACs, fridge, pump and workstations

Overnight scenario

At a typical night-time load of 2.5kW (1 AC, fridge and lights), the 30kWh battery runs for about 10.8 hours. The cheaper version's 15kWh runs for about 5.4 hours.

Estimates vary with actual load, battery reserve, temperature and conversion losses.

SEE THE ENERGY MOVE

Watch a day on this system.

Follow solar, battery and generator power through 24 hours. Change the building, weather or configuration to explore how the system responds with the grid off.

Building

00:00Night · grid off

Drag to rotate · arrow keys to turn

Solar available0 kW
Building demand0 kW
Usable battery charge0%
Generator output0 kW
Solar availableBuilding demandGeneratorBattery charge

Solar captured
Building energy
Lowest usable charge
Generator energy
View hourly energy data
Instantaneous power and battery charge, hourly samples
HourSolar kWLoad kWGenerator kWBattery %

The same day on diesel.

Compare generator fuel for the entire load with the generator backup required in this simulation.

Generator only
Solar + generator backup
Illustrative daily fuel saving
Simulation assumptions and limits

Illustrative model, not live monitoring or a measured weather forecast. The package’s modelled daily solar energy is distributed from 6am to 6pm. Weather multipliers are 125%, 100%, 55% and 25%; they are scenarios, not annual frequency claims. Home demand is weighted towards evenings; business demand towards 8am–6pm, with 35% more daily energy. Adjust daily load from 50% to 200%.

Battery usable capacity is 90% of nominal, starting at 75% of usable capacity at midnight. Charge and discharge efficiency are each 96%. Solar and battery delivery are limited to 90% of inverter kVA in kW. Generator power fills remaining demand, without charging the battery. This is a single illustrative day; its opening and closing battery charge may differ.

Fuel use per hour = 0.25 × supplied kW + 0.037 × generator kVA while running; generator rating is assumed equal to package inverter kVA. Fuel only; servicing, replacement, financing and grid costs are excluded.

Every detail, clearly listed.

Complete configuration specifications
Solar array8.7 kWp
Panels14 × Jinko Tiger Neo 620W N-type TOPCon (Tier-1)
InverterAurora 11kW hybrid
PhaseSingle-phase
Battery storage30 kWh
Battery chemistryLiFePO₄
Battery rating7-year warranty, over 6,000 cycles at 90% depth of discharge
Usable battery capacity27 kWh
Modelled daily generation33.3 kWh
Modelled monthly generation999 kWh

Explore the savings estimates.

Illustrative scenarios from this package’s existing planning model. Savings and payback are estimates, not guaranteed returns.

conservative

₦275,000.00modelled monthly savings

3 years estimated payback

base case

₦398,000.00modelled monthly savings

2 years estimated payback

optimistic

₦469,000.00modelled monthly savings

1.7 years estimated payback

FOLLOW THE RETURN OVER TIME

Your payback, made visible.

Adjust the assumptions to see cumulative savings cross the package investment.

Estimated simple payback—

Configuration investment: · follows the simulation configuration above.

Cumulative savings after maintenanceInitial investment
Year 10
Cumulative savings
Net after investment
Investment recovered

Simple, undiscounted estimate from the selected package’s savings assumptions. Defaults exclude maintenance until you enter a value. Financing, tariff changes, tax, inflation, replacement batteries and residual value are excluded. The day simulation and this long-term estimate are separate models; one day’s result is not multiplied into an annual guarantee.

Assumptions behind these estimates

Savings are the solar energy a system produces and the customer uses, valued at what that energy costs them today. Output is 1,397kWh per kWp a year, the Lagos figure for a well-oriented, unshaded array after system losses; we count 75% of it as used in homes and 90% in businesses, and give the battery no credit for charging from the grid, so the payback is conservative. Generator fuel is derived rather than assumed: litres/hour ≈ 0.25 × kW drawn + 0.037 × rated kVA, at ₦1,920/litre. The second term is fixed burn proportional to the set's size whether or not anything is plugged in, which is why an oversized generator costs more per kWh than one that is worked hard. Most Lagos generators run at 40–70% of rating; across that band fuel alone costs ₦607–₦702/kWh on a well-maintained engine, about ₦640/kWh at a typical 55% load, and around ₦800/kWh on a worn, lightly loaded one. Servicing, overhaul, managed-power premiums and diesel theft add another ₦60–₦120/kWh, which is what takes generator power past ₦700/kWh all-in. Band A grid is taken at ₦210/kWh. Conservative (₦366/kWh blended avoided cost): Band A home, 14–18 hours of mains, load weighted to the evening. Base case (₦531/kWh): Band B/C small business, roughly 10 hours of mains, mid-life generator. Optimistic (₦625/kWh): Band C/D commercial site with minimal grid and heavy daytime load. The more of your consumption falls in daylight hours, the faster the payback.

Pricing and sizing methodology

A clearer view of generator costs.

A 10kVA generator running 10 hours a day burns roughly 350–530 litres of diesel a month, depending on how hard it is worked. At ₦1,920 a litre that is ₦670k–₦1.0M a month in fuel alone, before servicing, oil changes and the diesel that goes missing. The same job as a 10kVA or 12kVA system, for less.

Fuel prices are model assumptions. Check the diesel price guide and request a site-specific comparison.

YOUR SPACE. YOUR POWER NEEDS.

Let’s build your power plan.

Tell us your location, appliances and backup needs. We’ll help confirm the right configuration and an itemised quotation.

Explore compatible system monitoring