SolepowerGet a quote
All packages

SME/Residential · Solepower Home 10

A Serious Solar System for a Serious Home, or a Small Office That Means Business

9.9 kWp solar · 10 kVA inverter · 30 kWh lithium battery

From ₦8,618,000.00

Choose your configuration below. Confirm current pricing and installation scope in a written quotation.

Jinko solar panel
16 panels
Hybrid inverter, illustrative model
1 inverter
Lithium battery, illustrative model
30 kWh battery

Equipment overview · exact models confirmed in your quote

9.9 kWpSolar array
10 kVAInverter capacity
30 kWhBattery storage
37.9 kWhModelled daily generation

Choose your configuration.

Compare equipment and battery capacity. Start with your actual loads and preferred backup hours.

Starter
Jinko solar panel
16 panels
Hybrid inverter, illustrative model
1 inverter
Lithium battery, illustrative model
15 kWh battery

Solepower Home 10 Starter

₦8,618,000.00

  • 9.9 kWp solar · 16 panels
  • SRNE 10kW hybrid
  • 15 kWh lithium battery
Request starter quote

Same panels. Add a second 15kWh pack later to reach 30kWh.

Published package figures are planning references. Confirm current equipment, availability and installation scope. Discuss payment options.

Is this the right fit?

Large 3–4 bedroom home or small office with up to 8 staff in Lagos

Large 3–4 bedroom flat or duplex in Magodo, Ajah, Omole or Lekki Phase 2

Small office with 5–8 staff, 2–3 AC units, desktop computers and network equipment

Business owner working from home: server, 2 ACs and full household appliances

Home or office currently running a 10kVA generator 8–12 hours a day

Household where several people work from home and daytime power matters

What this system can power.

Air conditioning

2 units (1.5HP) together

10kVA carries 2 split units plus the base load comfortably. A third is possible in sunshine hours with some care.

refrigeration

1 fridge and 1 upright freezer around the clock, or 2 fridges

lighting

Full property LED lighting inside and out

fans

4–5 ceiling fans

entertainment devices

3 TVs and 5 laptops or workstations

water pump

0.75HP borehole pump: yes, several runs a day

washing machine

Yes, 1–2 loads a day

microwave

Yes, moderate daily use

Loads to discuss before ordering

Three-phase equipment or continuous loads above 8kW.

Understand your battery runtime.

27 kWhUsable battery capacity
5.4 hoursAt 5 kW — 2 ACs, fridge and lights
3.6 hoursAt 7.5 kW — 2 ACs, fridge, workstations and lights

Overnight scenario

At a typical night-time load of 2.5kW (1 AC, fridge and lights), the 30kWh battery runs for about 10.8 hours. The cheaper version's 15kWh runs for about 5.4 hours.

Estimates vary with actual load, battery reserve, temperature and conversion losses.

SEE THE ENERGY MOVE

Watch a day on this system.

Follow solar, battery and generator power through 24 hours. Change the building, weather or configuration to explore how the system responds with the grid off.

Building

00:00Night · grid off

Drag to rotate · arrow keys to turn

Solar available0 kW
Building demand0 kW
Usable battery charge0%
Generator output0 kW
Solar availableBuilding demandGeneratorBattery charge

Solar captured
Building energy
Lowest usable charge
Generator energy
View hourly energy data
Instantaneous power and battery charge, hourly samples
HourSolar kWLoad kWGenerator kWBattery %

The same day on diesel.

Compare generator fuel for the entire load with the generator backup required in this simulation.

Generator only
Solar + generator backup
Illustrative daily fuel saving
Simulation assumptions and limits

Illustrative model, not live monitoring or a measured weather forecast. The package’s modelled daily solar energy is distributed from 6am to 6pm. Weather multipliers are 125%, 100%, 55% and 25%; they are scenarios, not annual frequency claims. Home demand is weighted towards evenings; business demand towards 8am–6pm, with 35% more daily energy. Adjust daily load from 50% to 200%.

Battery usable capacity is 90% of nominal, starting at 75% of usable capacity at midnight. Charge and discharge efficiency are each 96%. Solar and battery delivery are limited to 90% of inverter kVA in kW. Generator power fills remaining demand, without charging the battery. This is a single illustrative day; its opening and closing battery charge may differ.

Fuel use per hour = 0.25 × supplied kW + 0.037 × generator kVA while running; generator rating is assumed equal to package inverter kVA. Fuel only; servicing, replacement, financing and grid costs are excluded.

Every detail, clearly listed.

Complete configuration specifications
Solar array9.9 kWp
Panels16 × Jinko Tiger Neo 620W N-type TOPCon (Tier-1)
InverterSRNE 10kW hybrid
PhaseSingle-phase
Battery storage30 kWh
Battery chemistryLiFePO₄
Battery rating7-year warranty, over 6,000 cycles at 90% depth of discharge
Usable battery capacity27 kWh
Modelled daily generation37.9 kWh
Modelled monthly generation1137 kWh

Explore the savings estimates.

Illustrative scenarios from this package’s existing planning model. Savings and payback are estimates, not guaranteed returns.

conservative

₦312,000.00modelled monthly savings

2.9 years estimated payback

base case

₦452,000.00modelled monthly savings

2 years estimated payback

optimistic

₦533,000.00modelled monthly savings

1.7 years estimated payback

FOLLOW THE RETURN OVER TIME

Your payback, made visible.

Adjust the assumptions to see cumulative savings cross the package investment.

Estimated simple payback—

Configuration investment: · follows the simulation configuration above.

Cumulative savings after maintenanceInitial investment
Year 10
Cumulative savings
Net after investment
Investment recovered

Simple, undiscounted estimate from the selected package’s savings assumptions. Defaults exclude maintenance until you enter a value. Financing, tariff changes, tax, inflation, replacement batteries and residual value are excluded. The day simulation and this long-term estimate are separate models; one day’s result is not multiplied into an annual guarantee.

Assumptions behind these estimates

Savings are the solar energy a system produces and the customer uses, valued at what that energy costs them today. Output is 1,397kWh per kWp a year, the Lagos figure for a well-oriented, unshaded array after system losses; we count 75% of it as used in homes and 90% in businesses, and give the battery no credit for charging from the grid, so the payback is conservative. Generator fuel is derived rather than assumed: litres/hour ≈ 0.25 × kW drawn + 0.037 × rated kVA, at ₦1,920/litre. The second term is fixed burn proportional to the set's size whether or not anything is plugged in, which is why an oversized generator costs more per kWh than one that is worked hard. Most Lagos generators run at 40–70% of rating; across that band fuel alone costs ₦607–₦702/kWh on a well-maintained engine, about ₦640/kWh at a typical 55% load, and around ₦800/kWh on a worn, lightly loaded one. Servicing, overhaul, managed-power premiums and diesel theft add another ₦60–₦120/kWh, which is what takes generator power past ₦700/kWh all-in. Band A grid is taken at ₦210/kWh. Conservative (₦366/kWh blended avoided cost): Band A home, 14–18 hours of mains, load weighted to the evening. Base case (₦531/kWh): Band B/C small business, roughly 10 hours of mains, mid-life generator. Optimistic (₦625/kWh): Band C/D commercial site with minimal grid and heavy daytime load. The more of your consumption falls in daylight hours, the faster the payback.

Pricing and sizing methodology

A clearer view of generator costs.

A 10kVA generator running 10 hours a day burns roughly 350–530 litres of diesel a month, depending on how hard it is worked. At ₦1,920 a litre that is ₦670k–₦1.0M a month in fuel alone, before servicing, oil changes and the diesel that goes missing. This system takes the daytime load off the generator and the battery carries the evening.

Fuel prices are model assumptions. Check the diesel price guide and request a site-specific comparison.

YOUR SPACE. YOUR POWER NEEDS.

Let’s build your power plan.

Tell us your location, appliances and backup needs. We’ll help confirm the right configuration and an itemised quotation.

Explore compatible system monitoring