| Average combined load (illustrative) | Hours | Nominal battery at 90% DoD / 92% efficiency |
|---|---|---|
| 1 kW | 8 | 9.7 kWh |
| 1.5 kW | 8 | 14.5 kWh |
| 2 kW | 8 | 19.3 kWh |
| 3 kW | 8 | 29.0 kWh |
Measure the load before choosing battery size
An inverter air conditioner varies its draw with room temperature, insulation, thermostat setting and compressor speed. Read the electrical input rating and measure a representative operating period. Include the refrigerator, fans, lights and other appliances that will share the battery.
Calculate nominal battery capacity
Nominal battery kWh = average combined load × hours ÷ (depth of discharge × inverter efficiency). At an assumed 90% depth of discharge and 92% inverter efficiency, a continuous 1kW load for 8 hours needs about 9.7kWh nominal before an additional reserve. This is an example, not a rating for a particular AC.
Check power as well as energy
The inverter and battery discharge power must handle simultaneous loads and compressor starting requirements. Several ACs may require phase balancing or staged operation. Panel capacity must support daytime cooling and replenish the planned night-time energy.
Questions answered
Can solar run AC overnight?
Yes, with a suitably sized inverter, battery and charging arrangement. Night-time cooling is supplied by stored energy or another available source.
Will a 5kWh battery run any AC all night?
No. Runtime depends on average load, usable capacity, losses and reserve settings. Ask for a calculation for your specific AC and room.